Opposite Impeller Pump

opposite-impeller-pump-

Opposite Impeller Pump Properties

-Horizontal shaft, split body, diffuser, multistage, closed impeller centrifugal pumps. 2 models from DN 40 to DN 50 discharge flange diameter.
-ARS-KC type pumps have long bearing life due to the opposite impeller design.
-Suction flanges comply with TS EN 1092 – 2 / PN 16 and discharge flanges comply with TS EN 1092 – 2 / PN 40. (Flanges in pumps with stainless steel body material comply with TS EN 1092 – 1 standard related pressure class.)
-In standard manufacturing, the suction flange is on the coupling side and on the right side, the discharge flange is on the other end and top (R 4/2).
-If flange positions other than standard manufacturing are desired, this request must be specified at the time of order.
-All impellers are balanced dynamically or statically in accordance with ISO 1940 class 6.3.
-Axial force is balanced with impeller balancing holes system.
-The direction of rotation is clockwise when viewed by the engine.
-TAR-KC type pumps use “grease-lubricated” bearings as standard.

Opposite Impeller Pump Technical Data

Discharge Flange  DN 40 – DN 50
Capacity  60 m3/h
Head  450 m
Frequancy  Three-phase 50 Hz – 60 Hz*
Tempreature of Pumped Liquid  From -20 °C to + 110 °C
Maximum Operating Pressure  30 bar (63 bar)*

Opposite Impeller Pump Applications:

-Power Plants
-Agricultural Irrigation and Drainage
-Oil Industry
-Building System
-Water Treatment and Pressurization
-Mining
-Chemial Industry
-Heating, Ventilating and Air Conditioning
-Fire Fighting
-Food and Beverage Industry
-Iron and Steel Indusrty

Your Success is Our Success