ARS-KC type pumps have long bearing life due to the opposite impeller design.
Suction flanges comply with TS EN 1092 – 2 / PN 16 and discharge flanges comply with TS EN 1092 – 2 / PN 40. (Flanges in pumps with stainless steel body material comply with TS EN 1092 – 1 standard related pressure class.)
In standard manufacturing, the suction flange is on the coupling side and on the right side, the discharge flange is on the other end and top (R 4/2).
If flange positions other than standard manufacturing are desired, this request must be specified at the time of order.
All impellers are balanced dynamically or statically in accordance with ISO 1940 class 6.3.
Axial force is balanced with impeller balancing holes system.
The direction of rotation is clockwise when viewed by the engine.
TAR-KC type pumps use “grease-lubricated” bearings as standard.